Shock efficacy of subcutaneous implantable cardioverter-defibrillator for prevention of sudden cardiac death: Initial multicenter experience

75Citations
Citations of this article
86Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Recently, subcutaneous implantable cardioverter-defibrillator (S-ICD) has become available. The aim of our study was to assess the efficacy of S-ICD in a clinical setting. Methods and Results: Between June 2010 and July 2011, 40 consecutive patients (42±15 years; body mass index, 27±6 kg/m2; left ventricular ejection fraction, 47±15%; 28 men) received an S-ICD for primary (n=17) or secondary prevention (n=23 [58%]) at 3 institutions in Germany. Intraoperative defibrillation efficacy testing failed in 1 patient with severely reduced left ventricular ejection fraction; testing was effective in all other patients. All episodes stored in the S-ICD were analyzed for appropriate and inappropriate detection, as well as effective shock delivery to convert ventricular tachyarrhythmia into sinus rhythm. During a median follow-up of 229 (interquartile range, 116-305) days, 4 patients experienced 21 episodes, with correct detection of ventricular tachyarrhythmia and subsequent shock therapy. A total of 28 shocks were delivered in these 4 patients. Mixed logistic regression modeling revealed a shock efficacy of 96.4% (95% CI, 12.8%-100%). The efficacy of first shocks, however, was only 57.9% (95% CI, 35.6%-77.4%). Four episodes were incorrectly classified as ventricular tachyarrhythmia, which led to inappropriate shock delivery in 2 patients. Conclusions: Ineffective shock delivery may occur in patients with S-ICD, even after successful intraoperative testing. Multicenter trials are required with close monitoring of safety and efficacy end points to identify patients who may be at risk for shock failure. © 2012 American Heart Association, Inc.

Cite

CITATION STYLE

APA

Aydin, A., Hartel, F., Schlüter, M., Butter, C., Köbe, J., Seifert, M., … Willems, S. (2012). Shock efficacy of subcutaneous implantable cardioverter-defibrillator for prevention of sudden cardiac death: Initial multicenter experience. Circulation: Arrhythmia and Electrophysiology, 5(5), 913–919. https://doi.org/10.1161/CIRCEP.112.973339

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free