Abstract

Importance: Aortic stenosis (AS) is a major public health challenge with a growing therapeutic landscape, but current biomarkers do not inform personalized screening and follow-up. A video-based artificial intelligence (AI) biomarker (Digital AS Severity index [DASSi]) can detect severe AS using single-view long-axis echocardiography without Doppler characterization. Objective: To deploy DASSi to patients with no AS or with mild or moderate AS at baseline to identify AS development and progression. Design, Setting, and Participants: This is a cohort study that examined 2 cohorts of patients without severe AS undergoing echocardiography in the Yale New Haven Health System (YNHHS; 2015-2021) and Cedars-Sinai Medical Center (CSMC; 2018-2019). A novel computational pipeline for the cross-modal translation of DASSi into cardiac magnetic resonance (CMR) imaging was further developed in the UK Biobank. Analyses were performed between August 2023 and February 2024. Exposure: DASSi (range, 0-1) derived from AI applied to echocardiography and CMR videos. Main Outcomes and Measures: Annualized change in peak aortic valve velocity (AV-Vmax) and late (>6 months) aortic valve replacement (AVR). Results: A total of 12599 participants were included in the echocardiographic study (YNHHS: n = 8798; median [IQR] age, 71 [60-80] years; 4250 [48.3%] women; median [IQR] follow-up, 4.1 [2.4-5.4] years; and CSMC: n = 3801; median [IQR] age, 67 [54-78] years; 1685 [44.3%] women; median [IQR] follow-up, 3.4 [2.8-3.9] years). Higher baseline DASSi was associated with faster progression in AV-Vmax(per 0.1 DASSi increment: YNHHS, 0.033 m/s per year [95% CI, 0.028-0.038] among 5483 participants; CSMC, 0.082 m/s per year [95% CI, 0.053-0.111] among 1292 participants), with values of 0.2 or greater associated with a 4- to 5-fold higher AVR risk than values less than 0.2 (YNHHS: 715 events; adjusted hazard ratio [HR], 4.97 [95% CI, 2.71-5.82]; CSMC: 56 events; adjusted HR, 4.04 [95% CI, 0.92-17.70]), independent of age, sex, race, ethnicity, ejection fraction, and AV-Vmax. This was reproduced across 45474 participants (median [IQR] age, 65 [59-71] years; 23559 [51.8%] women; median [IQR] follow-up, 2.5 [1.6-3.9] years) undergoing CMR imaging in the UK Biobank (for participants with DASSi ≥0.2 vs those with DASSi

Cite

CITATION STYLE

APA

Oikonomou, E. K., Holste, G., Yuan, N., Coppi, A., McNamara, R. L., Haynes, N. A., … Khera, R. (2024). A Multimodal Video-Based AI Biomarker for Aortic Stenosis Development and Progression. JAMA Cardiology, 9(6), 534–544. https://doi.org/10.1001/jamacardio.2024.0595

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free