Reduction of fluoroscopic exposure using a new fluoroscopy integrating technology in a 3D-mapping system during pulmonary vein isolation with a circular multipolar irrigated catheter

9Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

Abstract

Pulmonary vein isolation (PVI) is a cornerstone therapy in patients with atrial fibrillation (AF). With increasing numbers of PVI procedures, demand arises to reduce the cumulative fluoroscopic radiation exposure for both the physician and the patient. New technologies are emerging to address this issue. Here, we report our first experiences with a new fluoroscopy integrating technology in addition to a current 3D-mapping system. The new fluoroscopy integrating system (FIS) with 3D-mapping was used prospectively in 15 patients with AF. Control PVI cases (n = 37) were collected retrospectively as a complete series. Total procedure time (skin to skin), fluoroscopic time, and dose-area-product (DAP) data were analyzed. All PVI procedures were performed by one experienced physician using a commercially available circular multipolar irrigated ablation catheter. All PVI procedures were successfully undertaken without major complications. Baseline characteristics of the two groups showed no significant differences. In the group using the FIS, the fluoroscopic time and DAP were significantly reduced from 571 ± 187 seconds versus 1011 ± 527 seconds (P = 0.0029) and 4342 ± 2073 cGycm2 versus 6208 ± 3314 cGycm2 (P = 0.049), respectively. Mean procedure time was not significantly affected and was 114 ± 31 minutes versus 104 ± 24 minutes (P = 0.23) by the FIS. The use of the new FIS with the current 3D-mapping system enables a significant reduction of the total fluoroscopy time and DAP compared to the previous combination of 3D-mapping system plus normal fluoroscopy during PVI utilizing a circular multipolar irrigated ablation catheter. However, the concomitant total procedure time is not affected. Thus, the new system reduces the radiation exposure for both the physicians and patients.

Cite

CITATION STYLE

APA

Blockhaus, C., Schmidt, J., Kurt, M., Clasen, L., Brinkmeyer, C., Katsianos, E., … Makimoto, H. (2016). Reduction of fluoroscopic exposure using a new fluoroscopy integrating technology in a 3D-mapping system during pulmonary vein isolation with a circular multipolar irrigated catheter. International Heart Journal, 57(3), 299–303. https://doi.org/10.1536/ihj.15-399

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free