Abstract
The essential points of interesting technical matters concerning the design of POF cable and accessories and its installation for Grand Coulee Dam in U.S.A. are discussed. Such difficult problems as extra high oil pressure in lower side pothead, oil drainage from cable, high cable pull tension and cable sliding down were all derived from the high elevation difference and successfully solved. Copyright 1971 by The Institute of Electrical and Electronics Engineers, Inc.
Cite
CITATION STYLE
Imai, T., Kikuchi, K., Takada, N., & Ishizu, K. (1971). Cable installation technique challenging sharp difference in land elevation. IEEE Transactions on Power Apparatus and Systems, PAS-90(4), 1883–1893. https://doi.org/10.1109/TPAS.1971.293183