Abstract
Purpose: To evaluate the feasibility of implementing fitting guides for multifocal contact lenses (MCLs) using the SimVis Gekko visual simulator and, through a preliminary assessment with a novel metric (3D-VA, which integrates visual acuity at multiple distances and patient visual needs), determine whether this combined approach can optimise initial MCL selection. Methods: Twenty presbyopic subjects participated in this study using two methods to select on-eye MCLs from 4 manufacturers: (1) using the first step of the fitting guide, according to the patient's addition need, to provide the MCLs recommended by the manufacturer and, (2) using SimVis Gekko simulations to obtain MCLs providing better 3D-VA, between the first and the first-alternative step of the fitting guides. Clinical measurements and metric calculations (3D-VA, perceptual score module, and direct preference) were conducted to compare the visual performance of the on-eye MCLs selected by both methods when differences existed. Results: SimVis Gekko selected the same combination of MCLs as the fitting guides in 59 % of the cases. In 28 %, SimVis Gekko chose the alternative step with differences greater than 0.05 in 3D-VA. In these latter cases, the 3D-VAs obtained with the on-eye MCLs indicated that SimVis Gekko selections were better in 62 % of cases, equal in 14 %, and worse in 24 %. The perceptual score module showed that SimVis Gekko selections were better in 62 % of cases, equal in 9 %, and worse in 29 %. The direct preference indicated that SimVis Gekko selections were better in 61 % of cases. Clinical measurements revealed that MCLs selected by SimVis Gekko had better Near Activity Visual Questionnaire scores than the fitting guide selection across all manufacturers (p = 0.02), indicating greater comfort and independence for near activities. Conclusions: SimVis Gekko can effectively replicate fitting guide steps and, in combination with the 3D-VA metric, has the potential to become a tool that helps practitioners enhance MCL wearer satisfaction. This approach could improve the adoption and visual performance of MCLs among the presbyopic population, streamlining the fitting process.
Author supplied keywords
Cite
CITATION STYLE
Esteban-Ibañez, E., Molina-Martín, A., Martínez-Plaza, E., Dorronsoro, C., Gambra, E., & Piñero, D. P. (2025). Improving multifocal contact lens fitting by replicating their fitting guides using the SimVis Gekko visual simulator. Contact Lens and Anterior Eye, 48(6). https://doi.org/10.1016/j.clae.2025.102468
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.