Abstract
Liquid level measurement is an important requirement in many industrial applications. Several measurement approaches have been studied previously, including inductance methods suitable for an infinite surface area. In this paper, we presented a novel approach based on the high frequency electromagnetic induction technique for the measurement of liquid level with a small surface area. In this situation, the analytical approach we developed previously is no long valid. Sensitivity analysis was carried out and the optimal coil configuration of the sensor proposed. Experiment results have confirmed the validity and effectiveness of our proposed approach based the electromagnetic sensing principle.
Author supplied keywords
Cite
CITATION STYLE
Zhao, Q., Xu, K., Xie, Y., & Yin, W. (2015). Measurement of liquid level with a small surface area using high frequency electromagnetic sensing technique. In Conference Record - IEEE Instrumentation and Measurement Technology Conference (Vol. 2015-July, pp. 1414–1419). Institute of Electrical and Electronics Engineers Inc. https://doi.org/10.1109/I2MTC.2015.7151483