Removal of acetaldehyde gas using wet scrubber coupled with photo-Fenton reaction

8Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The feasibility of the combined air-cleaning method, which consisted of a wet scrubber and the photo-Fenton reaction, in the removal of gaseous acetaldehyde was evaluated. An acetaldehyde-gas removal efficiency of 99% was achieved in the one-pass test (residence time of 17 s) using an inlet acetaldehyde-gas concentration of 1000 ppb at an initial total-iron-ion concentration of 50 mg L−1 and initial hydrogen peroxide concentration of 630 mg L−1. Even at the low initial total-iron-ion concentration of 4 mg L−1, a removal efficiency of 92% was achieved. The acetaldehyde removal efficiency was relatively independent of the initial hydrogen peroxide concentration. UV irradiation further augmented the rate of the photo-Fenton reaction leading to enhanced acetaldehyde-gas removal.

Cite

CITATION STYLE

APA

Tokumura, M., Mizukoshi, A., Noguchi, M., Wada, Y., Usami, Y., Yamaki, T., & Yanagisawa, Y. (2016). Removal of acetaldehyde gas using wet scrubber coupled with photo-Fenton reaction. AIMS Environmental Science, 3(1), 159–167. https://doi.org/10.3934/environsci.2016.1.159