Testosterone measurement by isotope-dilution liquid chromatography-tandem mass spectrometry: Validation of a method for routine clinical practice

145Citations
Citations of this article
53Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Immunoassay is unsatisfactory for measuring the testosterone concentrations typically found in women. Bench-top tandem mass spectrometers are a viable alternative technology for measurements in the clinical laboratory. Methods: We used stable-isotope dilution liquid chromatography-tandem mass spectrometry (ID/LC-MS/MS) to measure testosterone in plasma and serum. The sample volume was 50 μL in duplicate; preparation and analysis were carried out in a single tube, and a batch of 192 tubes was analyzed in 17.5 h. Results: Intra- and interassay imprecision was <15% in the range 0.3-49 nmol/L. Recovery of testosterone added to samples at concentrations of 0.625-20 nmol/L was 96% (CV = 12%; n = 26). Six samples were serially diluted with double charcoal-stripped serum to demonstrate linearity. Correlation (r2) with isotope-dilution gas chromatography-mass spectrometry for 20 pools of clinical samples (range, 0.5-38.5 nmol/L) was 0.99. Correlations with our extraction RIA were 0.97 for clinical samples from men (range, 8-46.3 nmol/L) and 0.66 for samples from women (range, 0.7-3.0 nmol/L), but were 0.35 for male samples containing <3 nmol/L testosterone and 0.77 for female samples containing >8 nmol/L. Various steroids added to double charcoal-stripped serum showed no interference at the retention time of the testosterone peak. Conclusions: The ID/LC-MS/MS method has improved accuracy compared with immunoassay. The low sample volume and simplicity, rapidity, and robustness of the method make it suitable for use as a high-throughput assay in routine clinical biochemistry laboratories. © 2005 American Association for Clinical Chemistry.

Cite

CITATION STYLE

APA

Cawood, M. L., Field, H. P., Ford, C. G., Gillingwater, S., Kicman, A., Cowan, D., & Barth, J. H. (2005). Testosterone measurement by isotope-dilution liquid chromatography-tandem mass spectrometry: Validation of a method for routine clinical practice. Clinical Chemistry, 51(8), 1472–1479. https://doi.org/10.1373/clinchem.2004.044503

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free