To examine the performance of the high efficiency particulate air (HEPA) filter, demonstration tests were done in various conditions, such as; normal condition, high temperature and earthquake condition, using conventional deep-pleat filters, 610-x610-x292-mm in size. The authors found that the HEPA filter acted efficiently enough in various conditions supposed in the air purification system of a nuclear plant. Some empirical formulae were proposed to express the performance of the filter. The test results were summarized from these three points: (1) decontamination factor (DF) of intact filters, (2) mechanical strength and (3) pinholes, because these three points are important criteria in evaluating the performance of HEPA filter systems. © 1990 Taylor & Francis Group, LLC.
Author supplied keywords
Cite
CITATION STYLE
Osaki, M., & Kanagawa, A. (1990). Performance of high efficiency particulate air filters. Journal of Nuclear Science and Technology, 27(9), 875–882. https://doi.org/10.1080/18811248.1990.9731266