A note on relay feedback identification under static load disturbances

1Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Obtaining the parameters for PID controllers based on limit cycle information for the process in a relay controlled feedback loop has become an accepted practical procedure. If the form of the plant transfer function is known, exact expressions for the limit cycle frequency and amplitude can be derived so that their measurements, assumed error free, can be used to calculate the true parameter value. In the literature, parameter estimation for an assumed form of the plant transfer function has generally been considered for disturbance free cases, except a recently published work of the author. In this paper additional simulation results are reported on exact parameter estimation from relay autotuning under static load disturbances.

Cite

CITATION STYLE

APA

Kaya, I. (2015). A note on relay feedback identification under static load disturbances. Journal of Electrical Engineering and Technology, 10(1), 395–400. https://doi.org/10.5370/JEET.2015.10.1.395