Improved cardiac motion self-gating

  • Han F
  • Rapacchi S
  • Hu P
N/ACitations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Cardiac motion self-gating is a technique where MRI signal is used to derive motion triggers instead of ECG, which might be problematic in high B0 field or cases where ECG is not accessible (e.g. fetal cardiac imaging). However, the performance of existing cardiac selfgating approaches have not yet enabled clinical utility. We propose and evaluate here a novel cardiac self-gating strategy that potentially improves the trigger detection accuracy and reliability. Methods: Conventional cardiac self-gating uses the k-space center from a radial acquisition to represent the cardiac motion and derive triggers. However, this strategy suffers from signal drifting and distortion shown in Fig.1a. We hypothesize that this is because the k-space center signal was modulated by the eddy currents from the varying phase-encoding(PE) or radial acquisition gradients. Such interference should be removed for robust self-gating. To test our hypothesis, we ran a Cartesian breath-held cardiac cine sequence with phase-encoding gradient turned off. We used Principle Component Analysis(PCA) to extract the cardiac motion signal from the acquired data. Trigger is then detected by finding the local maximum with an adaptive threshold. Our method differs from other cardiac self-gating techniques in four aspects: 1)The whole k-space center-line is used instead of the center point only; 2)Coil arrays were used instead of a single coil; 3)The self-gating signal is derived from repeatedly acquired non-phase-encoded k-space center-line and is therefore free of aforementioned signal interference. 4)PCA is used to further reduce any residual interference. Fig.2 shows a potential implementation in a cardiac MRI sequence. It consists of a self-gating mode where the k-space center-line is repeatedly acquired and an imaging mode where k-space is sampled. The sequence switches from self-gating mode, where the PE gradients are turned off, to imaging mode when a new trigger is detected and switches back after imaging to wait for the next trigger. Results: Fig.1b shows the cardiac self-gating signal and trigger generated by the proposed method on the same subject for Fig.1a. Fig.1c & d show the result from a 3T scanner where the quality of ECG is poor while our self-gating method could still provide accurate triggers. Based on data from 8 healthy volunteers, the overall trigger detection rate was 99% (one failed due to non-ideal breath-holding) and the average temporal variability of triggers was ±7.79 ms using the ECG as reference. On 3 subjects using the k-space center point only as previously described, the overall detection rate was only 65%. Conclusions: Our data demonstrates that the proposed cardiac selfgating method can significantly reduce the drift and distortion of the self-gating signal and therefore improve cardiac trigger detection accuracy and reliability. Future work will be focused on implementing the technique in an imaging sequence as Fig.2.

Cite

CITATION STYLE

APA

Han, F., Rapacchi, S., & Hu, P. (2013). Improved cardiac motion self-gating. Journal of Cardiovascular Magnetic Resonance, 15, P83. https://doi.org/10.1186/1532-429x-15-s1-p83

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free