Transapical aortic valve implantation: Mid-term outcome from the SOURCE registry

38Citations
Citations of this article
33Readers
Mendeley users who have this article in their library.

Abstract

Objectives: Transapical (TA) aortic valve implantation using the Edwards SAPIEN™ bioprosthesis was commercially introduced in Europe in January 2008. Limited data on the mid-term results are available. Methods: Using data from the SOURCE-Registry (largest consecutive cohort treated using Edwards SAPIEN™ bioprosthesis in Europe), we report on the mid-term results (≥30 days-2 years) of TA patients. Results: Between November 2007 and December 2009, a total of 1387 patients from 38 European centres underwent TA aortic valve implantation. The mean follow-up is 14.9 months, with 1004 patients who completed 1 year and 464 patients who completed the 2-year follow-up. The mean age of patients was 80.6 ± 7.1 years with a logistic-EuroSCORE of 27.6%. The main co-morbidities were coronary artery disease (55.8%), previous bypass grafting (25.5%), porcelain aorta (10.2%), previous stroke (6.5%) and peripheral vascular disease (26.4%). A total of 840 patients (60.6%) received a 26 mm and 535 (38.6%) a 23 mm Edwards SAPIEN™ bioprosthesis. Survivals at 30 days, 1 year and 2 years were 88.7, 73.8 and 65.1%, respectively. Causes of the 276 deaths observed between >30 days and 2-year follow-up were cardiac in 86 patients (31.2%), non-cardiac in 142 (51.4%) and unknown in 48 (17.4%). Cardiac causes of death included heart failure (33.7%), sudden cardiac death (33.7%), myocardial infarct (8.1%), endocarditis (5.8%) and others (18.6%). Non-cardiac deaths were related to pulmonary disease (21.1%), cancer (12.7%), renal failure (11.3%), stroke (10.6%), gastrointestinal disease (7.7%) and others (36.6%). Using univariable and multivariable analyses, logistic EuroSCORE, renal insufficiency and liver diseases were identified as independent predictors of 2-year mortality. Conclusions: These results demonstrate that in elderly patients with severe co-morbidities, TA aortic valve implantation results in excellent mid-term results. Causes of death during the mid-term follow-up are mainly non-cardiac and related to co-morbidities. © The Author 2012. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Cite

CITATION STYLE

APA

Wendler, O., Walther, T., Schroefel, H., Lange, R., Treede, H., Fusari, M., … Thomas, M. (2013). Transapical aortic valve implantation: Mid-term outcome from the SOURCE registry. European Journal of Cardio-Thoracic Surgery, 43(3), 505–512. https://doi.org/10.1093/ejcts/ezs297

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free