Comparison of ex-vivo high-resolution episcopic microscopy with in-vivo four-dimensional high-resolution transvaginal sonography of the first-trimester fetal heart

18Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objective To compare the capability of three-dimen-sional (3D) reconstructed images produced by high-resolution episcopic microscopy (HREM) with that of in-vivo four-dimensional high-resolution transvaginal sonography (4D-HRTVS) to discern morphological features of the first-trimester human fetal heart. Methods This was a prospective study of fetal hearts between 9 and 14 weeks' gestation. For ex-vivo 3D analysis, 30 human fetal hearts (at 9 + 0 to 14 + 6 weeks) were retrieved from surgical terminations of pregnancy. The specimens were embedded in resin and episcopic ('block-face') imaging was used to obtain a digital volume dataset (HREM) using 3-micron slicing. 4D-HRTVS was performed in 28 separate pregnancies at 10 + 2 to 14 + 0 weeks using a Voluson E8 ultrasound machine with volumetric transvaginal RIC 6-12-MHz transducers. Heart volumes obtained by both methods were compared to assess their ability to demonstrate first-trimester cardiac morphology. Comparisons were made in the transverse and sagittal planes, and using volume rendering. Results All hearts were structurally normal, although abdominal situs was not examined in the isolated hearts that underwent HREM. 4D-HRTVS demonstrated each of the complete five transverse cardiac views in 32-86% of cases. HREM showed four features unique to the first-trimester human heart: prominent atrial appendages, spiral ventricular arrangement, prominent coronary arteries and thickened arterial walls. 4D-HRTVS could demonstrate the first two, but ultrasound resolution was too poor to quantify wall thickness and demonstrate coronary arteries in the 3-5-mm diameter heart. Conclusions 4D-HRTVS showed limited morphological features of the first-trimester fetal heart compared with HREM. HREM provides a gold standard of ex-vivo imaging against which developments in ultrasound resolution could be compared. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Cite

CITATION STYLE

APA

Gindes, L., Matsui, H., Achiron, R., Mohun, T., Ho, S. Y., & Gardiner, H. (2012). Comparison of ex-vivo high-resolution episcopic microscopy with in-vivo four-dimensional high-resolution transvaginal sonography of the first-trimester fetal heart. Ultrasound in Obstetrics and Gynecology, 39(2), 196–202. https://doi.org/10.1002/uog.9068

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free