Quantification of periaortic adipose tissue in contrast-enhanced CT angiography: technical feasibility and methodological considerations

4Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

To examine the feasibility of the quantification of abdominal periaortic fat tissue (PaFT) (tissue within − 45 to − 195 HU) in enhanced CT-angiographies compared to unenhanced CT-scans and identify methodological issues affecting its clinical implementation. Using OsirixMD, PaFT volume and mean HU value were retrospectively measured within a 5 mm periaortic ring in paired unenhanced and enhanced abdominal aortic CT-scans. The correlation between PaFT values was examined in a derivation cohort (n = 101) and linear regression analysis produced correction factors to convert values from enhanced into values from unenhanced CTs. The conversion factors were then applied to enhanced CTs in a different validation cohort (n = 47) and agreement of corrected enhanced values with values from unenhanced scans was evaluated. Correlation between PaFT Volume und Mean HU from enhanced and unenhanced scans was very high (r > 0.99 and r = 0.95, respectively, p < 0.0001 for both). The correction factors for PaFT Volume and Mean HU were 1.1057 and 1.0011. Potential confounding factors (CT-kilovoltage, slice thickness, mean intraluminal contrast density, aortic wall calcification, longitudinal variation of intraluminal contrast density, aortic diameter) showed no significant effect in a multivariate regression analysis (p > 0.05). Bland-Altman analysis of corrected enhanced and unenhanced values showed excellent agreement and Passing–Bablok regression confirmed minimal/no residual bias. PaFT can be quantified in enhanced CT-angiographies very reliably. PaFT Volume scores are very consistently slightly underestimated in enhanced scans by about 10%, while the PaFT Mean HU value remains practically constant and offers distinct methodological advantages. However, a number of methodological issues remain to be addressed.

Cite

CITATION STYLE

APA

Mamopoulos, A. T., Freyhardt, P., Touloumtzidis, A., Zapenko, A., Katoh, M., & Gäbel, G. (2022). Quantification of periaortic adipose tissue in contrast-enhanced CT angiography: technical feasibility and methodological considerations. International Journal of Cardiovascular Imaging, 38(7), 1621–1633. https://doi.org/10.1007/s10554-022-02561-8

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free