Abstract
Human body naturally contains complex electrical signals ranging from the mechanism of the brain, heart, and muscles. Electromyography (EMG) is the development of biomedical engineering devices used to record electrical signal activity produced by muscles. The signal produced by the muscle has a very small amplitude, therefore, an amplifier circuit is required to read the signal using microcontroller. In this study, EMG signal amplification was carried out periodically to reduce errors that might occur if only charged to one signal amplifier. Signal reading was performed by conducting 5 different basic hand movements. Muscle signal activity during relaxed conditions had an amplitude of 0.05 V. Moreover, it conveyed an amplitude of 0.27 V up to 2.62 V with a signal gain of 10.350 when the muscle did different movements. The K-NN algorithm was used to classify EMG signals and determined the hand motion output used as a basic electronic control system. Results showed success rate of 88%. Failures when carrying out basic electronic control was due to the signal classification processes that had not met the parameters and the signal amplitude that was almost similar to another signal.
Author supplied keywords
Cite
CITATION STYLE
Ulum, M., Rozi, F., & Ibadillah, A. F. (2020). Signal Classification and Electromyography (EMG) Instrumentation Design as Basic Electronic Control System. In Journal of Physics: Conference Series (Vol. 1569). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/1569/3/032081