Submicron-precision particle characterization in microfluidic impedance cytometry with double differential electrodes

47Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Submicron-precision particle characterization is crucial for counting, sizing and identifying a variety of biological particles, such as bacteria and apoptotic bodies. Microfluidic impedance cytometry has been attractive in current research for microparticle characterization due to its advantages of label-free detection, ease of miniaturization and affordability. However, conventional electrode configurations of three electrodes and floating electrodes have not yet demonstrated the capability of probing submicron particles or microparticles with a submicron size difference. In this study, we present a label-free high-throughput (∼800 particles per second) impedance-based microfluidic flow cytometry system integrated with a novel design of a double differential electrode configuration, enabling submicron particle detection (down to 0.4 μm) with a minimum size resolution of 200 nm. The signal-to-noise ratio has been boosted from 13.98 dB to 32.64 dB compared to a typical three-electrode configuration. With the proposed microfluidic impedance cytometry, we have shown results of sizing microparticles that accurately correlate with manufacturers' datasheets (R2= 0.99938). It also shows that population ratios of differently sized beads in mixture samples are consistent with the results given by commercial fluorescence-based flow cytometry (within ∼1% difference). This work provides a label-free approach with submicron precision for sizing and counting microscale and submicron particles, and a new avenue of designing electrode configurations with a feature of suppressing the electrical noise for accomplishing a high signal-to-noise ratio in a wide range of frequencies. This novel double differential impedance sensing system paves a new pathway for real-time analysis and accurate particle screening in pathological and pharmacological research.

Cite

CITATION STYLE

APA

Zhong, J., Liang, M., & Ai, Y. (2021). Submicron-precision particle characterization in microfluidic impedance cytometry with double differential electrodes. Lab on a Chip, 21(15), 2869–2880. https://doi.org/10.1039/d1lc00481f

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free