Sepsis surveillance: An examination of parameter sensitivity and alert reliability

2Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objective: To examine performance of a sepsis surveillance system in a simulated environment where modifications to parameters and settings for identification of at-risk patients can be explored in-depth. Materials and Methods: This was a multiple center observational cohort study. The study population comprised 14 917 adults hospitalized in 2016. An expert-driven rules algorithm was applied against 15.1 million data points to simulate a system with binary notification of sepsis events. Three system scenarios were examined: a scenario as derived from the second version of the Consensus Definitions for Sepsis and Septic Shock (SEP-2), the same scenario but without systolic blood pressure (SBP) decrease criteria (near SEP-2), and a conservative scenario with limited parameters. Patients identified by scenarios as being at-risk for sepsis were assessed for suspected infection. Multivariate binary logistic regression models estimated mortality risk among patients with suspected infection. Results: First, the SEP-2-based scenario had a hyperactive, unreliable parameter SBP decrease >40mmHg from baseline. Second, the near SEP-2 scenario demonstrated adequate reliability and sensitivity. Third, the conservative scenario had modestly higher reliability, but sensitivity degraded quickly. Parameters differed in predicting mortality risk and represented a substitution effect between scenarios. Discussion: Configuration of parameters and alert criteria have implications for patient identification and predicted outcomes. Conclusion: Performance of scenarios was associated with scenario design. A single hyperactive, unreliable parameter may negatively influence adoption of the system. A trade-off between modest improvements in alert reliability corresponded to a steep decline in condition sensitivity in scenarios explored.

Cite

CITATION STYLE

APA

Amland, R. C., Burghart, M., & Overhage, J. M. (2019). Sepsis surveillance: An examination of parameter sensitivity and alert reliability. JAMIA Open, 2(3), 339–345. https://doi.org/10.1093/jamiaopen/ooz014

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free