In a low-frequency ultrasonic guided wave dual-probe flaw inspection of a square steel bar with a finite length boundary, the flaw reflected pulse wave cannot be identified using conventional time monitoring when the flaw is located near the reflection terminal; therefore, the conventional ultrasonic echo method is not applicable and results in a non-detection zone. Using analysis and simulations of ultrasonic guided waves for the inspection of a square steel bar, the reasons for the appearance of the non-detection zone and its characteristics were analyzed and the range of the non-detection zone was estimated. Subsequently, by extending the range of the conventional detection time domain, the envelope of the specific reflected pulse signal was extracted by a combination of simulations and related envelope calculations to solve the problem of the non-detection zone in conventional inspection methods. A comparison between the simulation and the experimental results demonstrate that the solution is feasible. This study has certain practical significance for ultrasonic guided wave structural monitoring.
CITATION STYLE
Zhang, L., Yang, Y., Wei, X., & Yao, W. (2018). The study of non-detection zones in conventional long-distance ultrasonic guided wave inspection on square steel bars. Applied Sciences (Switzerland), 8(1). https://doi.org/10.3390/app8010129