Ambient Mass Spectrometry and Machine Learning-Based Diagnosis System for Acute Coronary Syndrome

2Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Aims: The purpose of this study is to establish a novel diagnosis system in early acute coronary syndrome (ACS) using probe electrospray ionization-mass spectrometry (PESI-MS) and machine learning (ML) and to validate the diagnostic accuracy. Methods: A total of 32 serum samples derived from 16 ACS patients and 16 control patients were analyzed by PESI-MS. The acquired mass spectrum dataset was subsequently analyzed by partial least squares (PLS) regression to find the relationship between the two groups. A support vector machine, an ML method, was applied to the dataset to construct the diagnostic algorithm. Results: Control and ACS groups were separated into the two clusters in the PLS plot, indicating ACS patients differed from the control in the profile of serum composition obtained by PESI-MS. The sensitivity, specificity, and accuracy of our diagnostic system were all 93.8%, and the area under the receiver operating characteristic curve showed 0.965 (95% CI: 0.84–1). Conclusion: The PESI-MS and ML-based diagnosis system are likely an optimal solution to assist physicians in ACS diagnosis with its remarkably predictive accuracy.

Cite

CITATION STYLE

APA

Tran, Q. N. N., Moriguchi, T., Ueno, M., Iwano, T., & Yoshimura, K. (2024). Ambient Mass Spectrometry and Machine Learning-Based Diagnosis System for Acute Coronary Syndrome. Mass Spectrometry, 13(1). https://doi.org/10.5702/massspectrometry.A0147

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free