Abstract
Purpose: In bone surgery specialties, like orthopedics, neurosurgery, and oral and maxillofacial surgery patient safety and treatment success depends on the accurate implementation of computer-based surgical plans. Unintentional plan deviations can result in long-term functional damage to the patient. With on-site teleoperation, the surgeon operates a slave robot with a physically-decoupled master device, while being directly present at the operation site. This allows the surgeon to perform surgical tasks with robotic accuracy, while always remaining in the control loop. Methods: In this study the master- and slave-side accuracy of an on-site teleoperated miniature cooperative robot (minaroHD) is evaluated. Master-side accuracy is investigated in a user study regarding scale factor, target feed rate, movement direction and haptic guidance stiffness. Scale factors are chosen to correspond to primarily finger, hand, and arm movements. Slave-side accuracy is investigated in autonomous milling trials regarding stepover, feed rate, movement direction, and material density. Results: Master-side user input errors increase with increasing target feed rate and scale factor, and decrease with increasing haptic guidance stiffness. Resulting slave-side errors decrease with increasing scale factor and are < 0.07 mm for optimal guidance parameters. Slave-side robot position errors correlate with the feed rate but show little correlation with stepover distance. For optimal milling parameters, the 95th percentile of tracked slave-side position error is 0.086 mm with a maximal error of 0.16 mm. Conclusion: For optimal guidance and milling parameters, the combined error of 0.23 mm is in the range of the dura mater thickness (< 0.27 mm) or mandibular canal wall (~ 0.85 mm). This corresponds to safety margins in high-demand surgical procedures like craniotomies, laminectomies, or decortication of the jaw. However, for further clinical translation, the performance and usability of on-site teleoperated milling must be further evaluated for real-life clinical application examples with consideration of all error sources in a computer-assisted surgery workflow.
Author supplied keywords
Cite
CITATION STYLE
Drobinsky, S., de la Fuente, M., Puladi, B., & Radermacher, K. (2023). Accuracy of on-site teleoperated milling with haptic assistance. International Journal of Computer Assisted Radiology and Surgery, 18(11), 1969–1976. https://doi.org/10.1007/s11548-023-02983-2
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.