Cardiac arrest with pulseless electrical activity rhythm in newborn infants: A case series

35Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.

Abstract

The 2015 neonatal resuscitation guidelines added ECG to assess an infant's heart rate when determining the need for resuscitation at birth. However, a recent case report raised concerns about this technique in the delivery room. We report four cases of pulseless electrical activity during neonatal cardiopulmonary resuscitation in levels II-III neonatal intensive care units in Canada (Edmonton [n=3] and Winnipeg [n=1]). Healthcare providers should be aware that pulseless electrical activity can occur in newborn infants during cardiopulmonary resuscitation. We propose an adapted neonatal resuscitation algorithm to include pulseless electrical activity. Furthermore, in compromised newborns, heart rate should be assessed using a combination of methods/techniques to ensure accurate heart rate assessment. When ECG displays a heart rate but the infant is unresponsive, pulseless electrical activity should be suspected and chest compression should be started.

Cite

CITATION STYLE

APA

Luong, D., Cheung, P. Y., Barrington, K. J., Davis, P. G., Unrau, J., Dakshinamurti, S., & Schmölzer, G. M. (2019). Cardiac arrest with pulseless electrical activity rhythm in newborn infants: A case series. Archives of Disease in Childhood: Fetal and Neonatal Edition, 104(6), F572–F574. https://doi.org/10.1136/archdischild-2018-316087