The effect of contrast agents on left ventricular parameters calculated by a threshold-based software module: does it truly matter?

14Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The acquisition of short-axis (SA) cine magnetic resonance (MR) images after the administration of contrast agent (CA) is a common, time-saving technique, but a decreased difference in the blood-myocardium contrast on these steady-state free precession (SSFP) cine scans could change the calculated parameters when using threshold-based papillary and trabecular muscle (PTM) quantification. We studied the effect of CA on the parameters calculated from pre- and post-CA SA cine images in noncompaction cardiomyopathy (NC-CMP) and healthy (H) participants using a threshold-based module. A total of 39 individuals (20 patients and 19 healthy) were included prospectively in this study. After the pre-CA SA images were acquired, i.v. gadobutrol (GA) or gadobenate dimeglumine (GD) (GA vs. GD: NC-CMP = 12 vs. 8; C = 12 vs. 7) was administered, and SA scans were repeated after two minutes. A threshold-based PTM software was used for postprocessing. Pre-CA and post-CA SA images were analyzed, and the parameters were compared in both the NC-CMP and H groups. The left ventricular volumes were significantly larger, while the left ventricular myocardial (LVmass) and trabecular mass (LVtrab) values were significantly smaller on the post-CA scans (NC-CMP: pre-CA vs. post-CA, EDV: 74.0 ± 13.6 vs. 81.1 ± 16.3 ml/m2, ESV: 25.3 ± 7.3 vs. 30.1 ± 11.2 ml/m2, LVmass-ED: 82.5 ± 17.5 vs. 75.7 ± 15.9 g/m2, LVtrab-ED: 25.0 ± 6.6 vs. 18.9 ± 4.7 g/m2; Healthy: preCA vs. post-CA, EDV: 69.7 ± 11.9 vs. 72.2 ± 10.7 ml/m2, ESV: 22.6 ± 5.7 vs. 23.9 ± 6.3 ml/m2, LVmass-ED: 71.3 ± 13.6 vs. 68.7 ± 13.9 g/m2, LVtrab-ED: 19.4 ± 2.6 vs. 16.2 ± 3.0 g/m2; p < 0.05). The decreased blood-myocardium contrast difference on post-CA SSFP SA cine images leads to altered cardiac parameters when using threshold-based software for evaluation.

Cite

CITATION STYLE

APA

Szűcs, A., Kiss, A. R., Suhai, F. I., Tóth, A., Gregor, Z., Horváth, M., … Vágó, H. (2019). The effect of contrast agents on left ventricular parameters calculated by a threshold-based software module: does it truly matter? International Journal of Cardiovascular Imaging, 35(9), 1683–1689. https://doi.org/10.1007/s10554-019-01587-9

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free