Abstract
We describe the design, construction and performance of a Ring Imaging Cherenkov Detector (RICH) constructed to identify charged particles in the CLEO experiment. Cherenkov radiation occurs in LiF crystals, both planar and ones with a novel "sawtooth"-shaped exit surface. Photons in the wavelength interval 135-165 nm are detected using multi-wire chambers filled with a mixture of methane gas and triethylamine vapor. Excellent π/K separation is demonstrated. © 2005 Elsevier B.V. All rights reserved.
Author supplied keywords
Cite
CITATION STYLE
Artuso, M., Ayad, R., Bukin, K., Efimov, A., Boulahouache, C., Dambasuren, E., … Smith, A. (2005). The CLEO RICH detector. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 554(1–3), 147–194. https://doi.org/10.1016/j.nima.2005.07.056