Abstract
A dual enhancing strategy has been employed to develop electrochemical immunosensor for the ultrasensitive detection of AFP, which is enhanced by poly-dopamine functionalized N-doped multi-walled carbon nanotube (PDA-N-MWCNT) and the nanocomposite of graphene loaded Au@Pt mesoporous nanodendrites. The fabricated immunosensor exhibited a wide linear range of 0.1 pg/mL-10 ng/mL, with an ultralow detection limit of 0.05 pg/mL. The good performance of the developed immunosensor could be contributed to (1) PDA-N-MWCNT supplied good biocompatible surface for immobilizing primary antibody (Ab1); (2) PDA-N-MWCNT modified electrode endowed more electrochemical active area, which can effectively improve the sensitivity of the immunosensor; (3) graphene could load high amount of good conductive and high electrocatalytic active Au@Pt nanodendrites for signal amplification. The results imply that the as-fabricated immunosensors have great potential for clinic usage.
Author supplied keywords
Cite
CITATION STYLE
Jiao, L., Mu, Z., Zhu, C., Wei, Q., Li, H., Du, D., & Lin, Y. (2016). Graphene loaded bimetallic Au@Pt nanodendrites enhancing ultrasensitive electrochemical immunoassay of AFP. Sensors and Actuators, B: Chemical, 231, 513–519. https://doi.org/10.1016/j.snb.2016.03.034
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.