Intestinal Ultrasound Early on in Treatment Follow-up Predicts Endoscopic Response to Anti-TNFa Treatment in Crohn’s Disease

50Citations
Citations of this article
38Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: To assess treatment response, objective measures are superior to clinical improvement in Crohn's disease [CD]. Intestinal ultrasound [IUS] is an attractive, non-invasive alternative to endoscopy, demonstrating early transmural changes after treatment initiation. Therefore, we investigated IUS and contrast-enhanced ultrasound [CEUS] to predict [early] endoscopic treatment response. Methods: Consecutive patients with endoscopically active CD, starting anti-TNFα therapy, were included. Clinical, biochemical, IUS, and CEUS parameters at baseline [T0], after 4-8 weeks [T1] and 12-34 weeks [T2] were collected. The most severely inflamed segment at endoscopy (highest segmental Simplified Endoscopic Score for Crohn's Disease [SES-CD]) and IUS (highest segmental bowel wall thickness [BWT]) was identified. At T2, endoscopic response [decrease in SES-CD ≥ 50%] and remission [SES-CD = 0] were scored. Results: A total of 40 patients were included: 14 reached endoscopic remission and 17 endoscopic response. At T1 (3.1 mm [1.9-4.2] vs 5.3 mm [3.8-6.9], p = 0.005) and T2 (2.0 mm [1.8-3.1] vs 5.1 [3.0-6.3] mm, p = 0.002) BWT was lower in patients with endoscopic remission. At T1 and T2, 18% (area under the receiver operating curve [AUROC]: 0.77; odds ratio [OR]: 10.80, p = 0.012) and 29% [AUROC: 0.833; OR: 37.50, p = 0.006] BWT decrease predicted endoscopic response, respectively. To determine endoscopic remission, BWT 3.2 mm was most accurate [AUROC: 0.94; OR: 39.42, p < 0.0001] at T2. In addition, absence of colour Doppler signal [OR: 13.76, p = 0.03] and the CEUS parameter wash-out rate [OR: 0.76, p = 0.019] improved the prediction model. Conclusions: Reduction in BWT, already after 4-8 weeks of follow-up, predicted endoscopic response and remission. CEUS parameters were of limited value. Furthermore, we have provided accurate cut-offs for BWT reflecting endoscopic response and remission at different time points.

Cite

CITATION STYLE

APA

De Voogd, F., Bots, S., Gecse, K., Gilja, O. H., D’haens, G., & Nylund, K. (2022). Intestinal Ultrasound Early on in Treatment Follow-up Predicts Endoscopic Response to Anti-TNFa Treatment in Crohn’s Disease. Journal of Crohn’s and Colitis, 16(10), 1598–1608. https://doi.org/10.1093/ecco-jcc/jjac072

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free