Comparison of inter- and intraobserver agreement between three types of fetal volume measurement technique (XI VOCAL™, VOCAL™ and multiplanar)

33Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives To compare the new XI VOCAL™ (eXtended Imaging Virtual Organ Computer-aided Analysis) for three-dimensional (3D) ultrasound measurement of fetal volume with the conventional multiplanar technique and a rotational method using VOCAL™. Methods We acquired 3D volume datasets from 30 fetuses at 11-14 weeks of gestation using a commercially available ultrasound system. Fetal volume was calculated using XI VOCAL (with 5, 10, 15 and 20 slices), multiplanar (1-mm interval) and VOCAL (with 12°,18° and 30° rotation) techniques. The level of agreement for interobserver and intraobserver variability was determined and evaluated for all methods and reliability was assessed. Results Fetal volume measurements obtained using XI VOCAL (10 slices) showed good correlation with those obtained using VOCAL (18°)(r = 0.940, P = 0.076; intraclass correlation coefficient (ICC), 0.962 (95% CI, 0.920-0.982), P = 0.182), and XI VOCAL (15 slices) showed good correlation with VOCAL (12°)(r = 0.961, P = 0.092; ICC, 0.979 (95% CI, 0.957-0.990), P = 0.190). The mean difference between paired measurements by the XI VOCAL (10 slices) and VOCAL (18°) methods was 1.00 mL, while that by the XI VOCAL (15 slices) and VOCAL (12°) methods was 0.90 mL. 95% limits of agreement were -2.80 to 4.80 between XI VOCAL (10 slices) and VOCAL (18°)and-1.90 to 3.70 between XI VOCAL (15 slices) and VOCAL (12°). There was a small difference in the time required to complete the fetal volume measurement between XI VOCAL and VOCAL when a similar number of slices or rotational steps was used (P < 0.05), XI VOCAL taking less time. Conclusion XI VOCAL (with 10, 15 and 20 slices) can be used interchangeably with the multiplanar technique (1-mm interval) for the measurement of fetal volume. XI VOCAL (10 slices) and VOCAL (18°) can be used interchangeably, as can XI VOCAL (15 slices) and VOCAL (12°), for the measurement of fetal volume. Copyright © 2009 ISUOG. Published by John Wiley & Sons, Ltd.

Cite

CITATION STYLE

APA

Cheong, K. B., Leung, K. Y., Chan, H. Y., Lee, Y. P., Yang, F., & Tang, M. H. Y. (2009). Comparison of inter- and intraobserver agreement between three types of fetal volume measurement technique (XI VOCALTM, VOCALTM and multiplanar). Ultrasound in Obstetrics and Gynecology, 33(3), 287–294. https://doi.org/10.1002/uog.6255

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free