Target volume and position variations during intensity-modulated radiotherapy for patients with nasopharyngeal carcinoma

21Citations
Citations of this article
26Readers
Mendeley users who have this article in their library.

Abstract

Purpose: Considerable anatomical changes occur during intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC). This study aimed to quantify volumetric and positional variations of the target volume during IMRT. Materials and methods: Twenty patients with locally advanced NPC who received concurrent (13 patients) or sequential (seven patients) chemoradiotherapy were prospectively recruited and underwent planning computed tomography (CT) and six repeat CTs (every five fractions). Each repeat CT was rigidly registered to the planning CT. Gross tumor volume (GTV) and elective clinical target volume (CTV) were manually delineated on each axial CT image. CTVs of the primary tumor and lymph nodes were expanded with 5 mm margins to corresponding GTVs, with necessary modifications. Volume loss, system and random errors, and the mean and three-dimensional vector displacements were calculated and compared statistically. Results: Volumes of the primary tumor and small (>1 cm, ≤3 cm) and large (.3 cm) positive neck lymph nodes decreased at a rate of 2.6%, 3.7%, and 3.9% per treatment day, respectively. CTVs of the primary tumor, lymph nodes, and elective region decreased 1.5%, 2.3%, and 0.3% per treatment day, respectively. Average displacements of the GTVs and CTVs were,1.3 mm in all directions. GTVs and CTVs of the large and small lymph nodes shifted medially by 0.8-1.3 and 0.6-1.2 mm, respectively, on average. Average three-dimensional displacements of the GTVs and CTVs were 3.4-4.3 mm and 2.5-3.7 mm, respectively. Volume loss and displacements in most directions were significantly larger in patients receiving concurrent chemoradiotherapy than in those receiving sequential therapy. Volume loss and displacements of the GTV of large nodes and elective CTV were significantly larger in male than in female patients. Conclusion: Volumetric and positional changes of the target volume were considerable, and volume loss increased as treatment time elapsed during IMRT for NPC. © 2013 Tan et al.

Cite

CITATION STYLE

APA

Tan, W., Li, Y., Han, G., Xu, J., Wang, X., Li, Y., & Hu, D. (2013). Target volume and position variations during intensity-modulated radiotherapy for patients with nasopharyngeal carcinoma. OncoTargets and Therapy, 6, 1719–1728. https://doi.org/10.2147/OTT.S53639

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free