Abstract
Introduction: Distribution of microspheres after radioembolization can be accurately visualized using PET/CT. In this pictorial essay, we aim to demonstrate the value of 90Y-PET/CT after radioembolization. Methods: 90Y-PET/CT imaging was routinely performed after radioembolization at our institute. Patients were scanned the same day or the day after treatment, using a scanner with time-of-flight technology. We retrospectively reviewed all 90Y-PET/CTs from patients treated with radioembolization (both glass and resin microspheres) between January 2011 and January 2019. Five cases were selected that are illustrative of the added value of PET/CT after radioembolization. Results: 90Y-PET/CT allows for distribution assessment and dosimetry of 90Y-microspheres. It was used for the assessment of treatment success by visualization of tumor targeting, quantification of the absorbed dose, prediction of complications such as radioembolization-induced liver disease, and determining the required dosage for retreatment. Conclusion: PET/CT is an excellent modality for post-treatment imaging of 90Y-microspheres and could lead to improved dose planning and more personalized treatment.
Author supplied keywords
Cite
CITATION STYLE
Alsultan, A. A., Smits, M. L. J., Barentsz, M. W., Braat, A. J. A. T., & Lam, M. G. E. H. (2019). The value of yttrium-90 PET/CT after hepatic radioembolization: a pictorial essay. Clinical and Translational Imaging, 7(4), 303–312. https://doi.org/10.1007/s40336-019-00335-2