The present study describes a direct and an alternative HPLC method for the determination of etoposide in injectable dosage forms. Etoposide, an antineoplastic drug, was eluted through C18 ODS Hypersil column of 250 × 4.6 mm id with 5 μm particle size using simple mobile phase of methanol: water (1:1, v/v) at a flow rate of 1.0 mL min-1 and detected at 204 nm. The limit of detection of etoposide was 0.03 μg mL -1. The proposed method was found linear in the range of 0.25 μg mL-1 to 62.5 μg mL-1 and CV was 1.3% at 0.25 μg mL-1 , 0.48% at 3.90 μg mL-1 and 0.13% at 62.5 μg mL-1. The accuracy of the developed method for two injectable dosage forms was 99.4 and 99.7% with RSD of 0.3%. The validation results and statistical data demonstrate that the method is simple, cost effective, reproducible and suitable in quality analysis of the active ingredient and dosage form.
CITATION STYLE
Munawar Hayat, M., Ashraf, M., Nisar-Ur-Rehman, Nasim, F. U. H., Ahmad, I., Rahman, J., … Zubair Malik, M. (2011). HPLC determination of etoposide in injectable dosage forms. Journal of the Chilean Chemical Society, 56(4), 881–883. https://doi.org/10.4067/S0717-97072011000400012