Randomized crossover trial of 2-week Garment electrocardiogram with dry textile electrode to reveal instances of post-ablation recurrence of atrial fibrillation underdiagnosed during 24-hour Holter monitoring

7Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

Abstract

Background Atrial fibrillation (AF) is the most common arrhythmia and often recurs despite catheter ablation. The recurrence of AF is often underdiagnosed by standard 24-hour electrocardiogram (ECG) because of its transient and silent nature. A garment-style ECG with a highly conductive textile electrode made of poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOTPSS) and nanofiber (Garment ECG) has been developed that can provide longer-term continuous monitoring. This study investigated whether 2-week Garment ECG can reveal instances of AF recurrence in patients who are diagnosed as remaining in sinus rhythm by 24-hour Holter ECG. Methods The open-label randomized crossover study enrolled 67 patients (63.1±10.6 years old, 53 men) who had undergone initial AF ablation. Three months after ablation, patients were randomly assigned to group 1 (n = 35), 2-week Garment ECG followed by 24-hour Holter ECG, or group 2 (n = 32), 24-hour Holter ECG followed by 2-week Garment ECG. The detection of AF recurrence was compared between the two devices. Results The Garment ECG showed AF recurrence in 12 patients (18%) compared to 4 patients for the Holter ECG (6%, p = 0.008). The ECG acquisition rate was higher for Holter ECG than for Garment ECG (100.0% [interquartile range 100.0–100.0%] versus 82.4% [71.1–91.0%], p<0.001), but the Garment ECG provided longer total analysis time (11.0 days [9.0–12.2 days] for Garment; 1.0 day [1.0–1.0 day] for Holter, p<0.001). Conclusions Despite the lower ECG acquisition rate, the 2-week Garment ECG revealed instances of AF recurrence after ablation in patients who were underdiagnosed by 24-hour Holter ECG.

Cite

CITATION STYLE

APA

Machino, T., Aonuma, K., Maruo, K., Komatsu, Y., Yamasaki, H., Igarashi, M., … Ieda, M. (2023). Randomized crossover trial of 2-week Garment electrocardiogram with dry textile electrode to reveal instances of post-ablation recurrence of atrial fibrillation underdiagnosed during 24-hour Holter monitoring. PLoS ONE, 18(2 February). https://doi.org/10.1371/journal.pone.0281818

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free