Cryoballoon Versus High-Power, Short-Duration Radiofrequency Ablation for Pulmonary Vein Isolation in Patients With Paroxysmal Atrial Fibrillation: A Single-Center, Prospective, Randomized Study

23Citations
Citations of this article
40Readers
Mendeley users who have this article in their library.

Abstract

Background: The efficacy of cryoballoon pulmonary vein isolation (Cryo-PVI) is equivalent to that of radiofrequency pulmonary vein isolation in patients with paroxysmal atrial fibrillation (AF). We aimed to compare the efficacy and safety profile of Cryo-PVI and high-power, short-duration (HPSD) radiofrequency catheter ablation (RFCA) in patients with AF. Methods: We prospectively randomized 314 patients with paroxysmal AF (men, 71.3%; 59.9±10.9 years old) to either the Cryo-PVI group (n=156) or HPSD-RFCA group (n=158). Cavotricuspid isthmus ablation and linear ablation from the superior vena cava to the right atrial septum in addition to pulmonary vein isolation were carried out in the majority of patients in the HPSD-RFCA group. The primary end point was AF recurrence after a single procedure; secondary end points were the recurrence pattern, cardioversion rate, follow-up heart rate variability, and response to antiarrhythmic drugs. Results: After a mean follow-up of 9.8±5.1 months, the clinical recurrence rate did not significantly differ between the two groups (log-rank P=0.840). The rate of recurrence as atrial tachycardia (P>0.999), cardioversion (P=0.999), and 3-month heart rate variability (high frequency; P=0.506) did not significantly differ. During the final follow-up, sinus rhythm was maintained without antiarrhythmic drugs in 70.5% of the Cryo-PVI group and 73.4% of the HPSD-RFCA group (P=0.567). No significant difference was found in the major complication rate between the two groups (3.8% versus 0.6%; P=0.066), but total procedure time was significantly shorter in the Cryo-PVI group (78.5±20.2 versus 124.5±37.1 minutes; P<0.001). Conclusions: In patients with paroxysmal AF, the Cryo-PVI is an effective rhythm-control strategy with a shorter procedure time compared with the HPSD-RFCA.

Cite

CITATION STYLE

APA

Pak, H. N., Park, J. W., Yang, S. Y., Kim, T. H., Uhm, J. S., Joung, B., … Yu, H. T. (2021). Cryoballoon Versus High-Power, Short-Duration Radiofrequency Ablation for Pulmonary Vein Isolation in Patients With Paroxysmal Atrial Fibrillation: A Single-Center, Prospective, Randomized Study. Circulation: Arrhythmia and Electrophysiology, 14(9), E010040. https://doi.org/10.1161/CIRCEP.121.010040

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free