Correlation of Airway POCUS Measures with Screening and Severity Evaluation Tools in Obstructive Sleep Apnea: An Exploratory Study

1Citations
Citations of this article
4Readers
Mendeley users who have this article in their library.

Abstract

Background: Obstructive Sleep Apnea (OSA) is a common occurrence in the perioperative patient population but is often undiagnosed. Point-of-Care Ultrasound (POCUS) has emerged as a promising tool for perioperative assessment; however, its effectiveness in detecting the presence or severity of OSA needs to be evaluated. Objective: We assessed the ability of airway POCUS as a screening and severity evaluation tool for OSA by examining its correlation with STOP-BANG scores and the Apnea–Hypopnea Index (AHI). Design: Cross-sectional observational study. Setting: A single-center study in a tertiary care hospital between June 2020 to May 2021. Patients: Adult patients aged 18–65 with prior Polysomnography (PSG) for OSA workup were screened. Interventions: The participants completed the STOP-BANG questionnaire and subsequently underwent POCUS examinations, either pre- or post-surgery. Ten different POCUS views previously used for evaluating OSA were acquired in a predefined sequence, with subsequent measurements of airway parameters. Outcome measures: Generalized linear modeling was used to explore and assess the relationships between the measured parameters, STOP-BANG, and AHI scores (modeled continuously and categorized into risk levels of STOP-BANG and AHI). Results: A total of 260 patients were screened, of which 142 were enrolled and 127 completed the scanning studies. The median AHI was 16.71, while the STOP-BANG scores were mostly between 5 and 6, indicating a moderate-to-high OSA risk in the study population. Notably, only neck circumference was significantly associated with AHI severity (p = 0.012), whereas none of the other POCUS measures were. Among the POCUS measures, significant associations with STOP-BANG scores were observed for the Tongue Cross-Sectional Area (T-CSA) (p = 0.002), Retro-Palatal Diameter (RPD) (p = 0.034), Distance Between Lingual Arteries (DLA) (p = 0.034), and Geniohyoid Muscle Thickness (GMT) (p = 0.040). Conclusions: Neck circumference is a more reliable predictor of OSA severity (AHI) compared to other POCUS measurements. Many of the POCUS measures had a good correlation with the STOP-BANG scores, highlighting the utility of POCUS as a screening tool for OSA rather than as a severity evaluation tool.

Cite

CITATION STYLE

APA

Ravindranath, S., Ranganath, Y. S., Lemke, E., Behrens, M. B., Marian, A. A., Kalagara, H., … Sondekoppam, R. V. (2025). Correlation of Airway POCUS Measures with Screening and Severity Evaluation Tools in Obstructive Sleep Apnea: An Exploratory Study. Journal of Clinical Medicine, 14(14). https://doi.org/10.3390/jcm14144858

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free