Abstract

Background: Donor–recipient diameter discrepancy can be problematic when using an autologous great saphenous vein graft for internal jugular vein reconstruction. A triple-paneled method of saphenous vein grafting is one solution. Case presentation: A 54-year-old man with a thyroid papillary carcinoma underwent total thyroidectomy and bilateral neck dissection. An 8-cm segment of the right internal jugular vein was resected. For reconstruction, a 30-cm segment of the great saphenous vein was harvested and divided into three pieces of equal length. After opening each piece longitudinally, they were sutured together in a side-by-side fashion to create a cylinder that was used to reconstruct the internal jugular vein defect. The graft was patent 10 months after the surgery. Conclusion: The triple-paneled method is feasible for autologous great saphenous vein graft reconstruction of the internal jugular vein.

Cite

CITATION STYLE

APA

Miyamoto, S., Hidaka, T., Fukuoka, O., Fujisawa, K., & Okazaki, M. (2023). Internal jugular vein reconstruction using a triple-paneled great saphenous vein graft. World Journal of Surgical Oncology, 21(1). https://doi.org/10.1186/s12957-023-02902-4