An ultrasensitive UHPLC-ESI-MS/MS method augmented with a controlled microwave derivatization reaction for quantitation of vitamin D3 and its major metabolites in COVID-19 patients

6Citations
Citations of this article
33Readers
Mendeley users who have this article in their library.
Get full text

Abstract

It is established that vitamin D deficiency is correlated with the disease severity in COVID-19 patients. However, the reliable and sensitive quantitation of vitamin D3 (D3) and its metabolites remains a difficult challenge. Herein, a novel ultrasensitive and reliable UHPLC-ESI-MS/MS method was developed and validated for the quantitation of D3 and its major metabolites in COVID-19 patients. The mass spectral sensitivity was augmented via controlled microwave-assisted derivatization reaction (CMDR) with 2-nitrosopyridine (Pyr-NO) at 65 °C for 2 min. CMDR hyphenation with UHPLC-MS/MS improves detection sensitivity while shortening separation and derivatization reaction times. The precursor to product ion transitions for D3, 25-hydroxy D3 (25(OH)D3), 1,25-dihydroxy D3 (1,25-(OH)2D3) and calcipotriol (CPT) as an internal standard were m/z 493.4 → 231.3, m/z 509.4 → 231.3, m/z 525.4 → 247.3, and m/z 521.4 → 247.3; respectively. The separation of the formed derivatives was conducted using a gradient elution mode with mobile phase A: formic acid (0.1%) in water and mobile phase B: formic acid (0.1%) in acetonitrile. The elution started with 40% (v/v) of B for 0.3 min then increased linearly to 90% (v/v) at 2 min on an Agilent EclipsePlus C18 (50 × 2.1 mm, 1.8 μm) column at a flow rate of 0.3 mL min−1. The method was validated using FDA standards for bioanalytical method validation over a concentration range of 0.02–50 ng mL−1 with correlation coefficient ≥0.9987 and the lower limit of quantitation (LLOQ) were 0.02–0.05 ng mL−1 in human plasma. The developed method has demonstrated excellent comparability to a well-established chemiluminescent immunoassay (CLIA) method for the analysis of D3 metabolites in human samples. The developed UHPLC-ESI-MS/MS method was implemented for routine and reliable quantitation of D3 and its major metabolites in COVID-19 patients.

Cite

CITATION STYLE

APA

Ahmed, S. A., Khojah, H. M. J., Al-Thagfan, S. S., Alahmadi, Y. M., & Mohammed, Y. A. (2022). An ultrasensitive UHPLC-ESI-MS/MS method augmented with a controlled microwave derivatization reaction for quantitation of vitamin D3 and its major metabolites in COVID-19 patients. Talanta, 246. https://doi.org/10.1016/j.talanta.2022.123497

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free