The Use of Electrochemical Impedance Spectroscopy Method for Corrosion Resistance Evaluation of 2205 and 410s Stainless Steels in Aqueous Sodium Chloride Solution

6Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Corrosion behaviour of SS 2205 and SS 410s were investigated in various concentrations of aqueous sodium chloride solutions. Experimental work was carried out by using electrochemical impedance spectroscopy method at room temperature to evaluate the impedance of the system. Sodium chloride solutions were prepared with various concentration i.e. 1, 2, 3.5, 4 and 5 w.t%. The testing results were represented by Nyquist plot for both alloys. It was observed that the lowest corrosion resistance of both alloys was at 3,5% w.t NaCl which was similar to typical seawater solution. It was also observed that SS 2205 had better corrosion resistance along with greater impedance than the SS 410s in every NaCl concentration.

Cite

CITATION STYLE

APA

Rustandi, A., Sirait, G., Saputra, A., & Sadeli, Y. (2018). The Use of Electrochemical Impedance Spectroscopy Method for Corrosion Resistance Evaluation of 2205 and 410s Stainless Steels in Aqueous Sodium Chloride Solution. In IOP Conference Series: Materials Science and Engineering (Vol. 299). Institute of Physics Publishing. https://doi.org/10.1088/1757-899X/299/1/012053