Novel LC-MS/MS method for plasma vancomycin: Comparison with immunoassays and clinical impact

87Citations
Citations of this article
74Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Accurate quantification of vancomycin in plasma is important for adequate dose-adjustment. As literature suggests between-method differences, our first objective was to develop a novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for total vancomycin in human plasma and to compare frequently used immunoassays with this method. Secondly, we investigated the clinical impact of between-method quantification differences. Methods: For LC-MS/MS, lithiumheparin plasma was extracted by adding a precipitation reagent containing the internal standard (vancomycin-des-leucine). Analysis was performed on an Acquity TQD mass spectrometer equipped with an Acquity UPLC 2795 separations module. Our method was analytically validated and compared with four frequently used immunoassays from four different manufacturers. Vancomycin concentrations were clinically classified as toxic, therapeutic and sub-therapeutic. Clinical discordance was calculated using LC-MS/MS as a reference. Results:Anovel LC-MS/MSmethod using protein precipitation as sole pretreatment and an analysis time of 5.0 min was developed. The assay had a total imprecision of 2.6-8.5%, a limit of quantification of 0.3 mg/L and an accuracy ranging from 101.4 to 111.2%. Using LC-MS/MS as reference, three immunoassays showed a mean proportional difference within 10% and one showed a substantial mean proportional difference of >20%. Clinical discordant interpretation of the obtained concentrations ranged from 6.1 to 22.2%. Conclusions: We developed a novel LC-MS/MS method for rapid analysis of total vancomycin concentrations in human plasma. Correlation of the method with immunoassays showed a mean proportional difference N20% for one of the assays, causing discordant clinical interpretation in more than 1 out of 5 samples.

Cite

CITATION STYLE

APA

Oyaert, M., Peersman, N., Kieffer, D., Deiteren, K., Smits, A., Allegaert, K., … Pauwels, S. (2015). Novel LC-MS/MS method for plasma vancomycin: Comparison with immunoassays and clinical impact. Clinica Chimica Acta, 441, 63–70. https://doi.org/10.1016/j.cca.2014.12.012

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free