Abstract
It is recognized that exercise produces abnormally large increases in pulmonary artery pressure in patients with pulmonary vascular disease as a consequence of a variety of disorders, but the relationship between pressure and cardio-pulmonary exercise performance is poorly understood. This lack of understanding is due (in part) to difficulty making measurements of pulmonary haemodynamics using conventional fluid filled catheters. This article seeks to improve understanding by comparing variables measured during formal exercise testing with simultaneous measurements of pulmonary artery pressure using a micro-manometer tipped catheter. Ten patients with suspected pulmonary hypertension were studied using a micro-manometer tipped pulmonary artery catheter, during cardiopulmonary exercise testing. Ventilatory equivalents for oxygen and carbon dioxide correlated with the pulmonary artery pressure measured on exercise, but oxygen pulse and oxygen uptake did not. Ventilatory equivalents, noninvasively measured during exercise, may merit further study as potential surrogates of pulmonary artery pressure and hence be useful in identifying individuals at risk of developing pulmonary hypertension.
Author supplied keywords
Cite
CITATION STYLE
Raeside, D. A., Smith, A., Brown, A., Patel, K. R., Madhok, R., Cleland, J., & Peacock, A. J. (2000). Pulmonary artery pressure measurement during exercise testing in patients with suspected pulmonary hypertension. European Respiratory Journal, 16(2), 282–287. https://doi.org/10.1034/j.1399-3003.2000.16b16.x
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.