Abstract
AIM: To evaluate prospectively the hemodynamic performance of «BioLAB Mono» stentless bioprosthesis implanted into aortic position. MATERIAL AND METHODS: Twenty seven patients (mean age 71 (67; 73); 17 women) with severe aortic stenosis underwent aortic valve replacement with «BioLAB Mono» stentless bioprosthesis from 2012 to 2014. The valves were implanted into supra-annular position using continuous polypropylene suture. RESULTS: In the early postoperative period 1 patient (3.7%) died for acute heart failure. The mean aortic cross-clamping time was 81 (75; 90) min. Echocardiographic peak pressure gradient were 18 (16; 23) mmHg (postoperative). There were no cases of valve dysfunction in early postoperative period. Level of thrombocytes recovered after 10 days postoperatively. CONCLUSION: «BioLAB Mono» aortic bioprosthesis implantation is easy and reproducible. The valve has excellent hemodynamic performance in early postoperative period.
Cite
CITATION STYLE
Astapov, D. A., Demidov, D. P., & Semenova, E. I. (2016). Aortic valve replacement with stentless bioprosthesis. Khirurgiia, (5), 4–12. https://doi.org/10.17116/hirurgia201654-12