Abstract
Oseltamivir and oseltamivir carboxylate concentrations were measured in venous plasma, venous blood, and capillary blood taken simultaneously from 24 healthy volunteers. Median (range) venous-blood-to-plasma ratios were 1.42 (0.920 to 1.97) for oseltamivir and 0.673 (0.564 to 0.814) for oseltamivir carboxylate. Capillary blood/venous plasma ratios were 1.32 (0.737 to 3.16) for oseltamivir and 0.685 (0.502 to 1.34) for oseltamivir carboxylate. Oseltamivir concentrations in venous and capillary blood were similar. Oseltamivir carboxylate showed a time-dependent distribution between venous and capillary blood. Copyright © 2013, American Society for Microbiology. All Rights Reserved.
Cite
CITATION STYLE
Instiaty, I., Lindegardh, N., Jittmal, P., Hanpithakpong, W., Blessborn, D., Pukrittayakamee, S., … Tarning, J. (2013). Comparison of oseltamivir and oseltamivir carboxylate concentrations in venous plasma, venous blood, and capillary blood in healthy volunteers. Antimicrobial Agents and Chemotherapy, 57(6), 2858–2862. https://doi.org/10.1128/AAC.02408-12