Comparative study of the resolution efficiency of HPLC and HPTLC-densitometric methods for the analysis of mebeverine hydrochloride and chlordiazepoxide in their binary mixture

  • Michael A
  • Fayez Y
  • Nessim C
  • et al.
N/ACitations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

Accurate, rapid, and selective reversed phase HPLC and HPTLC-densitometric methods with UV detection have been developed and validated for simultaneous determination of a binary mixture of mebeverine hydrochloride (MVH) and chlordiazepoxide (CDZ) in their Co-formulation. For the HPLC method, ACE-126-2546 AQ C-18 column, (250×4.6 mm i.d., 5 μm particle size) in isocratic mode, with mobile phase containing 25 mM ammonium acetate buffer: acetonitrile in the ratio of (60:40, v : v ), pH adjusted to 3±0.2 by using hydrochloric acid, the flow rate of 1.0 mL/min and detection was performed at 260 nm. The retention times were 7.23±0.01 and 3.85±0.01 min for MVH and CDZ, respectively. For the HPTLC-densitometric method, the separation was performed using stationary phase pre-coated silica gel 60F 254  and mobile phase ethyl acetate: methanol (8:4, v : v ) were used and scanned at 222 nm with Camag TLC scanner controlled by Wincats Software. The R f values were 0.26±0.02 and 0.73±0.01 for MVH and CDZ, respectively. The linearity graphs for MVH and CDZ, respectively, were found to be linear over 1-50 μg/mL and 0.5-40.0 μg/mL with mean percentage recoveries 100.14±0.354 and 99.70±0.764 for HPLC method and 0.5-30.0 μg/band and 1-14 μg/band with mean percentage recoveries 100.29±0.665 and 99.68±0.987 for HPTLC-densitometric method. A comparative study of different analytical validation parameters such as accuracy, precision, specificity, robustness was conducted. The obtained results were statistically compared with those of the official methods; using student t -test, F-test, and one way ANOVA, showing no significant difference with respect to accuracy and precision.

Cite

CITATION STYLE

APA

Michael, A. M., Fayez, Y. M., Nessim, C. K., & Lotfy, H. M. (2016). Comparative study of the resolution efficiency of HPLC and HPTLC-densitometric methods for the analysis of mebeverine hydrochloride and chlordiazepoxide in their binary mixture. European Journal of Chemistry, 7(3), 315–321. https://doi.org/10.5155/eurjchem.7.3.315-321.1468

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free