Hydrogen gas concentration measurement in small area using raman lidar measurement technnology

5Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

When change of hydrogen(H2) gas concentration in a certain point is measured, non-contact measurement technology with high temporal and spatial resolution is necessary. In this study, H2 concentration in the small area of <1cm2 under the gas flow was measured by using a Raman lidar. Raman scattering light at the measurement point of 750mm ahead was detected by the Raman lidar. As a result, it was proved that the H2 concentration of more than 100ppm could be successfully measured.

Cite

CITATION STYLE

APA

Sugimoto, S., Asahi, I., & Shiina, T. (2018). Hydrogen gas concentration measurement in small area using raman lidar measurement technnology. In EPJ Web of Conferences (Vol. 176). EDP Sciences. https://doi.org/10.1051/epjconf/201817601019