Problems of ferrite content determination

3Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

Abstract

In this work five different methods – AC magnetometer, DC magnetometer, Feritscope, EBSD and X-ray diffraction - were compared with each other. These methods were used to determine the δ-ferrite content of samples. The limits, disadvantages and advantages of the applied methods were analyzed. The tested material was 2507 type super-duplex stainless steel. The samples were cold rolled and heat treated to modify their ferrite content.

Cite

CITATION STYLE

APA

Bögre, B., & Mészáros, I. (2020). Problems of ferrite content determination. Periodica Polytechnica Mechanical Engineering, 64(2), 150–158. https://doi.org/10.3311/PPME.15022