Effect of impact stress on microbial recovery on an agar surface

210Citations
Citations of this article
97Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Microbial stress due to the impaction of microorganisms onto an agar collection surface was studied experimentally. The relative recovery rates of aerosolized Pseudomonas fluorescens and Micrococcus luteus were determined as a function of the impaction velocity by using a moving agar slide impactor operating over a flow rate range from 3.8 to 40 liters/min yielding impaction velocities from 24 to 250 m/s. As a reference, the sixth stage of the Andersen Six-Stage Viable Particle Sizing Sampler was used at its operating flow rate of 28.3 liters/min (24 m/s). At a collection efficiency of close to 100% for the agar slide impactor, an increase in sampling flow rate and, therefore, in impaction velocity produced a significant decline in the percentage of microorganisms recovered. Conversely, when the collection efficiency was less than 100%, greater recovery and lower injury rates occurred. The highest relative rate of recovery (approximately 51% for P. fluorescens and approximately 62% for M. luteus) was obtained on the complete (Trypticase soy agar) medium at 40 and 24 m/s (6.4 and 3.8 liters/min), respectively. M. luteus demonstrated less damage than P. fluorescens, suggesting the hardy nature of the gram-positive strain versus that of the gram-negative microorganism. Comparison of results from the agar slide and Andersen impactors at the same sampling velocity showed that recovery and injury due to collection depends not only on the magnitude of the impaction velocity but also on the degree to which the microorganisms may be embedded in the collection medium. Impaction velocity, characterized by the sampler's operating flow rate and inlet design, is unique for each sampling device. The resulting impaction stress influences the recovery and injury of collected microorganisms and ultimately affects the measurement data for colony enumeration. This can be one of the most important reasons for variations that occur when using different sampling devices to measure bioaerosols from the same environment.

Cite

CITATION STYLE

APA

Stewart, S. L., Grinshpun, S. A., Willeke, K., Terzieva, S., Ulevicius, V., & Donnelly, J. (1995). Effect of impact stress on microbial recovery on an agar surface. Applied and Environmental Microbiology, 61(4), 1232–1239. https://doi.org/10.1128/aem.61.4.1232-1239.1995

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free