Gebauer SLc Original and Moria One-Use Plus automated microkeratomes for ultrathin Descemet's stripping automated endothelial keratoplasty preparation

8Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: We compared the SLc Original (SLc) and One-Use Plus (OUP) microkeratomes for ultrathin Descemet's stripping automated endothelial keratoplasty (DSAEK) lamella preparation and storage, vis-à-vis accuracy, endothelial cell loss (ECL) and lamellar surface roughness (LSR). Methods: Twenty-five human corneas were dissected with single-use heads of different sizes aiming for a posterior lamella (PL) thickness of 85 μm, after which they were incubated for 6 days in a 5% dextran medium. Before preparation (0 hr) and 1, 24, and 144 hr after dissection, ECL and corneal thickness (CCT) were measured by ultrasound pachymetry (USP) and optical coherence tomography (OCT). Lamellar surface roughness (LSR) was assessed by scanning electron microscopy (SEM) and evaluated by two masked observers. Results: Prior to cutting, CCTs did not differ between OCT and USP measurements, with a high correlation between the two modalities (r2 = 0.8; p < 0.0001). Both systems succeeded in UT lamella preparation (CCT 40–130 μm) in 88% of cases. The OUP heads cut significantly deeper than the according SLc counterparts (p = 0.001), while the variance did not differ. The mean PL thickness increased significantly in the following incubation period (p = 0.01) with no difference between the keratome groups. Endothelial cell density (ECD) decreased significantly from before to 1 hr after preparation (−5.6%; p = 0.04), with no changes in the following 144-hr incubation period and no differences between the OUP and SLc group. Lamellar surface roughness (LSR) did not differ between both systems. Conclusions: The SLc and the OUP system are both suited for the preparation of UT-DSAEK lamellae. Neither system differed significantly in variability, LSR or ECL, which did not increase during a 6-day incubation period.

Cite

CITATION STYLE

APA

Fuest, M., Salla, S., Hermel, M., Plum, W. J., Rütten, S., Plange, N., … Walter, P. (2016). Gebauer SLc Original and Moria One-Use Plus automated microkeratomes for ultrathin Descemet’s stripping automated endothelial keratoplasty preparation. Acta Ophthalmologica, 94(8), e731–e737. https://doi.org/10.1111/aos.13118

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free