Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients

70Citations
Citations of this article
143Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: Although several parameters have been proposed to predict the hemodynamic response to fluid expansion in critically ill patients, most of them are invasive or require the use of special monitoring devices. The aim of this study is to determine whether noninvasive evaluation of respiratory variation of brachial artery peak velocity flow measured using Doppler ultrasound could predict fluid responsiveness in mechanically ventilated patients.Methods: We conducted a prospective clinical research in a 17-bed multidisciplinary ICU and included 38 mechanically ventilated patients for whom fluid administration was planned due to the presence of acute circulatory failure. Volume expansion (VE) was performed with 500 mL of a synthetic colloid. Patients were classified as responders if stroke volume index (SVi) increased ≥ 15% after VE. The respiratory variation in Vpeakbrach(ΔVpeakbrach) was calculated as the difference between maximum and minimum values of Vpeakbrachover a single respiratory cycle, divided by the mean of the two values and expressed as a percentage. Radial arterial pressure variation (ΔPPrad) and stroke volume variation measured using the FloTrac/Vigileo system (ΔSVVigileo), were also calculated.Results: VE increased SVi by ≥ 15% in 19 patients (responders). At baseline, ΔVpeakbrach, ΔPPradand ΔSVVigileowere significantly higher in responder than nonresponder patients [14 vs 8%; 18 vs. 5%; 13 vs 8%; P < 0.0001, respectively). A ΔVpeakbrachvalue >10% predicted fluid responsiveness with a sensitivity of 74% and a specificity of 95%. A ΔPPradvalue >10% and a ΔSVVigileo>11% predicted volume responsiveness with a sensitivity of 95% and 79%, and a specificity of 95% and 89%, respectively.Conclusions: Respiratory variations in brachial artery peak velocity could be a feasible tool for the noninvasive assessment of fluid responsiveness in patients with mechanical ventilatory support and acute circulatory failure.Trial Registration: ClinicalTrials.gov ID: NCT00890071. © 2009 Monge García et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Monge García, M. I., Gil Cano, A., & Díaz Monrové, J. C. (2009). Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients. Critical Care, 13(5). https://doi.org/10.1186/cc8027

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free