Real-world safety and effectiveness outcomes of a zotarolimus-eluting stent: Final 3-year report of the RESOLUTE international study

9Citations
Citations of this article
31Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives We evaluated the safety and effectiveness of the Resolute™ zotarolimus-eluting stent (R-ZES) in real-world clinical practice through 3 years. Background A randomized comparison of the R-ZES and the XIENCE V™ everolimus-eluting stent showed no difference in any outcomes through 3-year follow-up in high-volume academic centers. RESOLUTE International is a confirmatory trial designed to evaluate the R-ZES in real-world clinical practice. Methods RESOLUTE International is a single arm, observational trial that enrolled 2,349 patients from 88 centers with only a few inclusion and exclusion criteria. The primary end-point was the composite of cardiac death and target vessel myocardial infarction (TV-MI) at 1 year. Secondary end-points include target lesion failure (TLF), target vessel revascularization (TVR), and their components, and stent thrombosis (ST). Results At 3 years 97.2% of patients completed clinical follow-up. The mean age was 63.4 ± 11.2 years, 77.8% were male, and 30.4% had diabetes. The average number of stents per patient was 1.6 ± 1.0; and mean stent length was 30.9 ± 20.5 mm. Dual antiplatelet therapy was used in 91.1% of patients at 1 year, 43.0% at 2 years, and 34.6% at 3 years. Cardiac death and TV-MI occurred in 161 patients (7.0%). There were 6 (0.3%) very late ST events for a total ST rate of 1.1% through 3 years. The rates of clinically driven target lesion revascularization (TLR), TVR, and TLF were 5.7%, 7.4%, and 11.4%, respectively. Conclusions The safety and effectiveness of the R-ZES through 3 years in this real-world all-comer study was consistent with previously reported all-comer trials. © 2013 The Authors. Journal of Interventional Cardiology Published by Wiley Periodicals, Inc.

Cite

CITATION STYLE

APA

Belardi, J. A., Widimský, P., Neumann, F. J., Mauri, L., & Albertal, M. (2013). Real-world safety and effectiveness outcomes of a zotarolimus-eluting stent: Final 3-year report of the RESOLUTE international study. Journal of Interventional Cardiology, 26(5), 515–523. https://doi.org/10.1111/joic.12051

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free