Abstract
This paper focuses on the results of computational fluid dynamics (CFD) modeling of radon concentration distribution in living areas within residences. The COMSOL Multiphysics® 5.3 software package has been employed for solving coupled momentum and species transport problems together with pseudo-reaction term modeling of the radon radioactive decay process. The reliability and verification of the simulation model was tested by comparing with available experimental data. The obtained results show the existence of stagnant zones where the concentration of radon is substantially higher than the average values. The impact of factors such as wind velocity, air tightness, and incoming radon flux were taken into consideration.
Author supplied keywords
Cite
CITATION STYLE
Spotar, S., Ibrayev, N., Uyzbayeva, A., & Atabayev, J. (2018). Non-uniformity of the indoor radon concentration under a convective mixing mechanism. International Journal of Environmental Research and Public Health, 15(12). https://doi.org/10.3390/ijerph15122826
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.