Improvement of the clinical applicability of the genomic grade index through a qRT-PCR test performed on frozen and formalin-fixed paraffin-embedded tissues

77Citations
Citations of this article
68Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Proliferation and tumor differentiation captured by the genomic grade index (GGI) are important prognostic indicators in breast cancer (BC) especially for the estrogen receptor positive (ER+) disease. The aims of this study were to convert this microarray index to a qRT-PCR assay (PCR-GGI), which could be realized on formalin fixed paraffin embedded samples (FFPE), and to assess its prognostic performance and predictive value of clinical benefit in early and advanced ER+ BC patients treated with tamoxifen. Methods: The accuracy and concordance of the PCR-GGI with the GGI was assessed using BC patients for which frozen and FFPE tissues as well as microarray data were available (n = 19). The evaluation of the prognostic value of the PCR-GGI was assessed on FFPE material using a consecutive series of 212 systemically treated early BC patients. The predictive performance for tamoxifen benefit was assessed using two ER+ BC populations treated either with adjuvant tamoxifen only (n = 77+139) or first-line tamoxifen for advanced disease (n = 270). Results: The PCR-GGI is based on the expression of 8 genes (4 representative of the GGI and 4 reference genes). A significant correlation was observed between the microarray-derived GGI and the qRT-PCR assay using frozen (ρ = 0.95, p < 10E-06) and FFPE material (ρ = 0.89, p < 10E-06). The prognostic performance of the PCR-GGI was confirmed on FFPE samples (HRunivar.= 1.89; [95CI:1.01-3.54], p = 0.05). The PCR-GGI further identified two subgroups of patients with statistically different time to distant metastasis free survival (DMFS) across the two cohorts of ER+ BC patients treated with adjuvant tamoxifen. Additionally, the PCR-GGI was associated with response to tamoxifen in the advanced setting (HRunivar.= 1.98; [95CI:1.51-2.59], p = 6.9E-07). Conclusion: PCR-GGI recapitulates in an accurate and reproducible manner the performances of the GGI using frozen and FFPE samples. © 2009 Toussaint et al; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Toussaint, J., Sieuwerts, A. M., Haibe-Kains, B., Desmedt, C., Rouas, G., Harris, A. L., … Sotiriou, C. (2009). Improvement of the clinical applicability of the genomic grade index through a qRT-PCR test performed on frozen and formalin-fixed paraffin-embedded tissues. BMC Genomics, 10, 424. https://doi.org/10.1186/1471-2164-10-424

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free