Abstract
The purpose of this study was to evaluate the fatigue property of Ti-5Al-13Ta alloy castings for dental application since dental prostheses are used under repetitive stress condition. Dumbbell-shaped cast specimens were prepared with a centrifugal casting machine and a magnesia-based mold material. Fatigue test was performed at 310 K in 0.9% NaCl solution under repetitive loading condition with the maximum cycles at 107. As a result, fatigue limit of Ti-5Al-13Ta alloy castings in NaCl solution was about 220 MPa, which was higher than those of CP-Ti, Ti-6Al-4V and Ti-6Al-7Nb alloys, previously reported. Clear striation was observed at the crack propagation area on the fracture surface. The ratio of fatigue limit to UTS was suggested to be 30% for Ti-5Al-13Ta alloy castings: this value was higher than those for Ti-6Al-4V and Ti-6Al-7Nb alloys. It was concluded that Ti-5Al-13Ta alloy castings showed good fatigue property in 0.9% NaCl solution as an α + β high-strength titanium alloy for dental prostheses. © 2006 The Japan Institute of Metals.
Author supplied keywords
Cite
CITATION STYLE
Doi, H., Yoneyama, T., Kobayashi, E., & Hanawa, T. (2006). Fatigue property of Ti-5Al-13Ta alloy dental castings in 0.9% NaCl solution. In Materials Transactions (Vol. 47, pp. 2444–2447). https://doi.org/10.2320/matertrans.47.2444
Register to see more suggestions