Impact of B0 field imperfections correction on BOLD sensitivity in 3D-SPARKLING fMRI data

2Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Static and dynamic (Formula presented.) field imperfections are detrimental to functional MRI (fMRI) applications, especially at ultra-high magnetic fields (UHF). In this work, a field camera is used to assess the benefits of retrospectively correcting (Formula presented.) field perturbations on Blood Oxygen Level Dependent (BOLD) sensitivity in non-Cartesian three-dimensional (3D)-SPARKLING fMRI acquisitions. Methods: fMRI data were acquired at 1 mm (Formula presented.) and for a 2.4s-TR while concurrently monitoring in real-time field perturbations using a Skope Clip-on field camera in a novel experimental setting involving a shorter TR than the required minimal TR of the field probes. Measurements of the dynamic field deviations were used along with a static (Formula presented.) map to retrospectively correct static and dynamic field imperfections, respectively. In order to evaluate the impact of such a correction on fMRI volumes, a comparative study was conducted on healthy volunteers. Results: Correction of (Formula presented.) deviations improved image quality and yielded between 20% and 30% increase in median temporal signal-to-noise ratio (tSNR).Using fMRI data collected during a retinotopic mapping experiment, we demonstrated a significant increase in sensitivity to the BOLD contrast and improved accuracy of the BOLD phase maps: 44% (resp., 159%) more activated voxels were retrieved when using a significance control level based on a p-value of 0.001 without correcting for multiple comparisons (resp., 0.05 with a false discovery rate correction). Conclusion: 3D-SPARKLING fMRI hugely benefits from static and dynamic (Formula presented.) imperfections correction. However, the proposed experimental protocol is flexible enough to be deployed on a large spectrum of encoding schemes, including arbitrary non-Cartesian readouts.

Cite

CITATION STYLE

APA

Amor, Z., Le Ster, C., Chaithya, G. R., Daval-Frérot, G., Boulant, N., Mauconduit, F., … Vignaud, A. (2024). Impact of B0 field imperfections correction on BOLD sensitivity in 3D-SPARKLING fMRI data. Magnetic Resonance in Medicine, 91(4), 1434–1448. https://doi.org/10.1002/mrm.29943

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free